Solar vfd

Efficient and user-friendly operation for solar pumping

Emotron VSR series drives offer reliable, cost-efficient and user-friendly operation. Soft start of pumps can avoid water hammer and improve lifetime of the system. The Emotron VSR series has been specially developed for solar water pumping. Built-in self adaptive high accuracy maximum power point tracking (MPPT) algorithm of VSR ensures maximum water flow output. The compatibility of VSR with ac as well as dc input gives user the flexibility to optimize the operation and improve reliability of operation. The function of dormant state at weak light, wake up at strong light, high water level dormant state, under-load pre- warning and other control protection functions can ensure normal operation of water pumps under changing operating conditions. Thanks to variety of specially designed features of VSR, it is truly the answer to your needs.

  Emotron VSR ordering codes and dimensional details

AC 110V/ AC 220V or DC 170V/ DC320V Input Supply

 

 

 

 

Model Recommended Solar Array Power Current  
  [kWp] [A] [kW] [A]           [kg] [mm]
VSR23 2p5 0.6 4.5 2.5 0.4  
VSR23 4p2 1.1 7.5 4.2 0.75          1.1 162x95x120
VSR23 7p5 2.25 10 7.5 1.5           1.5 173x110x135
VSR23 9p5 3.3 18 9.5 2.2  
VSR119p5 1.1 18 9.5 0.75          1.5 173x110x135

 

AC 380V&DC540V Input Supply

 

Model No. Recommended Solar Array Power Maximum Input DC

Current

Output Current A Motor kW Weight Dimensions [HxWxD]
  [kWp] [A] [A] [A] [kg] [mm]
VSR48003 1.1 4.5 2.5 0.75  

1.45

 

200X80X200

VSR48004 2.3 8 4.2 1.5
VSR48006 3.3 10 5.5 2.2
VSR48009 6.0 18 9.5 3.7, 4 2.5 186.6X116.6X175
VSR48013 8.9 20 13 5.5
VSR48017 11.0 30 17 7.5 3.5 249X146X181.7
VSR48024 15.0 32 24 11
VSR48032 20.0 42 32 15  

6.5

 

300X198X189.7

VSR48038 24.0 53 38 18.5
VSR48045 29.0 64 45 22

AC 380V&DC540V Input Supply

 

Model No. Recommended Solar Array Power Maximum Input DC Current Output Current A Motor kW Weight Dimensions [HxWxD]
  [kWp] [A] [kW] [A] [kg] [mm]
VSRE48003 1 4.5 2.5 0.75 0.85 150X75X117
VSRE48004 2 8 4.2 1.5
VSRE48006 3 10 5.5 2.2 1.45 171X93X130
VSRE48009 6 18 9.5 3.7, 4

*Note : For PMSM support model No with –P

Technical data  
PV Input  
Maximum Input DC Voltage VSR11: 450VDC VSR23: 450VDC VSR48: 800VDC
Recommended Voc Range VSR11: 170~350VDC

VSR23: 320~370VDC VSR48: 500~700VDC

Recommended MPPT Voltage Range VSR11: 140~240VDC

VSR23: 250~350VDC VSR48: 450~600VDC

Starting Voltage Range VSR11: 80~450VDC

VSR23: 120~450VDC VSR48: 230~800VDC

Motor Support IM, PMSM*
Grid or backup generator input  
Input Voltage VSR11: Single phase 110V (-15%~20%) VSR23: Single phase 220V (-15%~30%) VSR48: Three phase 380V (-15%~30%)
Output specification  
Rated output voltage 3PH – 110V for VSR11, 3PH – 220V for VSR23 & 380V for VSR48
Output frequency 0~600.00Hz(Default 0~50.00Hz)
Protection  
Built-in Protection Lighting Protection, over-current, over voltage, output phase-lose, under-load, under

voltage, short circuit, overheating, water pump run dry etc.

General Parameters  
Site conditions No direct sunshine, no dust, corrosive gas, combustible gas, oil mist, steam, dripping or

salinity etc.

Altitude 0~2000m (above 1000m, derate the capacity by 1% per 100m)
Environment Temperature -10°C~50°C (50°C~60°C with deration)
Humidity 5~95%, non-condensation
Vibration less than 5.9 m/s2     (0.6g)
Storage Temperature -20°C~+70°C
Efficiency Rated Power Run≥93%
Installation Wall or rail mounting
Protection Grade IP20
Cooling Forced air Cooling
Communication Modbus 485