ABB ACS550
Low voltage AC drives
ABB general purpose drives
ACS550
0.75 to 355 kW/1 to 500 hp
Build up your own ordering code using the type code key below or contact your local ABB drives sales office and let them know what you want. Use page 3 as a reference section for more information.
Type designation:
Product series Rating and types Voltages Construction Dimensions Options
ACS550 – 01 – 03A3 – 4 + B055
Contents
ABB general purpose drives, ACS550
Introduction to ACS550 4
Technical data 5
Ratings, types, voltages and construction 6
Dimensions 7
Electromagnetic compatibility 7
Assistant control panel 8
Options 8
Control interfaces 8
Plug-in options 9
External options 10
Cooling and fuses 12
Control connections 13
Drives service 14-15
ABB general purpose drives
ABB general purpose drives are simple to buy, install, configure and use, saving considerable time. They are widely available through ABB channel partners. The drives have common user and process interfaces with fieldbuses, common software tools for sizing, commissioning, maintenance and common spare parts.
Applications
ABB general purpose drives can be used in a wide range of industries. Typical applications include pump, fan and constant torque use, such as conveyors. ABB general purpose drives are ideal in those situations where there is a need for simplicity to install, commission and use and where customizing or special product engineering is not required.
Highlights
− FlashDrop tool
− Intuitive use with assistant control panel
− Swinging choke for superior harmonic reduction
− Vector control
− Coated boards for harsh environments
− Built-in category C2 EMC filter (1st environment) as standard
− Flexible fieldbus system with built-in Modbus and numerous internally mountable fieldbus adapters
− UL, cUL, CE, C-Tick and GOST R approved
− RoHS compliant
Feature Advantage Benefit
Energy efficiency counters
Several counters to illustrate saved energy (kWh), carbondioxide emissions (CO2) and cost in local currency.
Shows direct impact on energy bill and helps control operational expenditure (OPEX).
Load analyzer Load analyzer saves process data, such as current and torque values, which can be used to analyze the process
and dimensioning of the drive and motor.
Optimized dimensioning of the drive, motor and process.
FlashDrop tool Faster and easier drive setup and commissioning. Patented, fast, safe and trouble-free parametrization method without electricity.
Assistant control panel Two soft-keys, function of which changes according to the state of the panel.
Built-in help function via dedicated button.
Real-time clock, allows timed tracing of faults and setting of parameters to activate at various times of day.
Changed parameters -menu.
Easy commissioning.
Fast setup.
Easier configuration. Rapid fault diagnosis.
Quick access to recent parameter changes.
Commissioning assistants
PID controller, real-time clock, serial communications assistant, drive optimizer, startup assistant.
Easy setup of parameters.
Maintenance assistant Monitors consumed energy (kWh), running hours or motor rotation.
Intuitive features Noise optimization.
Increases switching frequency of drive when drive temperature is reduced.
Controlled cooling fan: the drive is cooled only when necessary. Choke Patented swinging choke – matches the right inductance to the
right load, thereby suppressing and reducing harmonics.
Takes care of preventative maintenance of drive, the motor or run application.
Considerable motor noise reduction.
Reduces inverter noise and improves energy efficiency. Reduces total harmonic distortion (THD) emissions up
to 25%.
Vector control Improved motor control performance. Enables wider range of applications.
Built-in EMC filter Category C2 (1st environment) and category C3 (2nd environment) RFI filters as standard.
No need for additional external filtering.
Brake chopper Built-in up to 11 kW. Reduced cost.
Connectivity Built-in Modbus using EIA-485.
Simple to install:
– Easy connection of cables
– Easy connection to external fieldbus systems through multiple
I/Os and plug-in options
Reduced cost.
Reduced installation time. Secure cable connections.
Mounting template Supplied separately with unit. Quick and easy to mark mounting screw holes on installation surface.
RoHS compliant ACS550 drives comply with EU Directive RoHS 2002/95/CE
restricting the use of certaing hazardous substances.
Environmentally friendly product.
Mains connection
Voltage and
3-phase, 380 to 480 V, +10/ -15%, 0.75 to 355 kW
Programmable control connections
Two analog inputs
power range
3-phase, 208 to 240 V, +10/ -15%, 0.75 to 75 kW Auto-identification of input line
Voltage signal
Current signal
0 (2) to 10 V, Rin > 312 k single-ended
0 (4) to 20 mA, Rin = 100 single-ended
Frequency 48 to 63 Hz
Power factor 0.98
Motor connection
Voltage 3-phase, from 0 to USUPPLY
Frequency 0 to 500 Hz
Potentiometer reference value Maximum delay Resolution Accuracy
10 V ± 2% max. 10 mA, R < 10 k
12 to 32 ms
0.1%
±1%
Continuous loading
capability
(constant torque at a max
Rated output current I2N
Two analog outputs
Accuracy
0 (4) to 20 mA, load < 500
±3%
ambient temperature of
Auxiliary voltage 24 V DC ±10%, max. 250 mA
40 °C)
Overload capacity (at a max. ambient temperature of 40 °C)
At normal use 1.1 x I2N for 1 minute every
10 minutes
At heavy-duty use 1.5 x I2hd for 1 minute every 10 minutes
Six digital inputs
Input impedance
Maximum delay
Three relay outputs
12 to 24 V DC with internal or external supply, PNP and NPN
2.4 k
5 ms ± 1 ms
Always 1.8 x I2hd for 2 seconds every 60 seconds
Maximum switching
Switching frequency
Default 4 kHz
voltage
250 V AC/30 V DC
Selectable 1 kHz, 2 kHz, 4 kHz, 8 kHz, 12 kHz
Acceleration time 0.1 to 1800 s
Deceleration time 0.1 to 1800 s
Speed control
Maximum switching current
Maximum continuous
current
6 A/30 V DC; 1500 V A/230 V AC
2 A rms
Open loop Closed loop Open loop
20% of motor nominal slip
0.1% of motor nominal speed
< 1% s with 100% torque step
Serial communication
EIA-485 Modbus protocol
Product compliance
Closed loop 0.5% s with 100% torque step
Torque control
Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC
Open loop
Closed loop Open loop Closed loop
Environmental limits
Ambient temperature
< 10 ms with nominal torque
< 10 ms with nominal torque
±5% with nominal torque
±2% with nominal torque
Quality assurance system ISO 9001
Environmental system ISO 14001
UL, cUL, CE, C-Tick and GOST R approvals
RoHS compliant
-15 to 50 oC No frost allowed. From 40 to 50 °C with derating.
Altitude
Output current
Rated current available at 0 to 1000 m. In altitudes from 1000 to 4000 m (3300 to 13,200 ft) above sea level, the derating is 1% for every
100 m (330 ft). If the installation site is higher than 2000 m (6600 ft) above sea level, please contact your local ABB distributor or office for
further information.
Relative humidity 5 to 95%, no condensation allowed
Degree of protection IP21 or IP54 ( 160 kW)
Enclosure colour NCS 1502-Y, RAL 9002, PMS 420 C
Contamination levels Transportation
Storage
Operation
IEC 721-3-3
No conductive dust allowed Class 1C2 (chemical gases), Class 1S2 (solid particles) Class 2C2 (chemical gases), Class 2S2 (solid particles) Class 3C2 (chemical gases), Class 3S2 (solid particles)
Type designation
Drive’s type designation (shown above and in column 7 of the tables on the right side) identifies your drive by construction,
3-phase supply voltage 380 to 480 V Wall-mounted units
Ratings Type designation Frame
current rating and voltage range. Once you have selected the
Normal use Heavy-duty use
size
type designation, the frame size (column 8) can be used to
determine the drives dimensions, shown on the next page.
Construction
“01” within the type designation (shown above) varies depending on the drive mounting arrangement, and power rating.
01 = wall-mounted
02 = free-standing
Voltages
The ACS550 is available in two voltage ranges:
4 = 380 to 480 V
2 = 208 to 240 V
Insert either “4” or “2”, depending on your chosen voltage, into the type designation shown above.
1.1 1.5 3.3 0.75 1 2.4 ACS550-01-03A3-4 R1
1.5 2 4.1 1.1 1.5 3.3 ACS550-01-04A1-4 R1
2.2 3 5.4 1.5 2 4.1 ACS550-01-05A4-4 R1
3 4 6.9 2.2 3 5.4 ACS550-01-06A9-4 R1
4 5.4 8.8 3 4 6.9 ACS550-01-08A8-4 R1
5.5 7.5 11.9 4 5.4 8.8 ACS550-01-012A-4 R1
7.5 10 15.4 5.5 7.5 11.9 ACS550-01-015A-4 R2
11 15 23 7.5 10 15.4 ACS550-01-023A-4 R2
15 20 31 11 15 23 ACS550-01-031A-4 R3
18.5 25 38 15 20 31 ACS550-01-038A-4 R3
22 30 45 18.5 25 38 ACS550-01-045A-4 R3
30 40 59 22 30 45 ACS550-01-059A-4 R4
37 50 72 30 40 59 ACS550-01-072A-4 R4
45 60 87 37 60 72 ACS550-01-087A-4 R4
55 100 125 45 75 96 ACS550-01-125A-4 R5
75 125 157 55 100 125 ACS550-01-157A-4 R6
90 150 180 75 125 156 ACS550-01-180A-4 R6
110 150 205 90 125 162 ACS550-01-195A-4 R6
132 200 246 110 150 192 ACS550-01-246A-4 R6
160 200 290 132 200 246 ACS550-01-290A-4 R6
Free-standing units
200 300 368 160 250 302 ACS550-02-368A-4 R8
250 400 486 200 350 414 ACS550-02-486A-4 R8
280 450 526 250 400 477 ACS550-02-526A-4 R8
315 500 602 280 450 515 ACS550-02-602A-4 R8
355 500 645 315 500 590 ACS550-02-645A-4 R8
3-phase supply voltage 208 to 240 V Wall-mounted units
Ratings Type designation Frame
Normal use Heavy-duty use
Normal use vs heavy-duty use. For the majority of pump, fan and conveyor applications, select “Normal use” figures. For high overload requirements, select “Heavy-duty use” figures. If in doubt contact your local ABB sales office or your drives distributor.
PN for kW = Typical motor power in 400 V at normal use
PN for hp = Typical motor power in 460 V at normal use
Phd for kW = Typical motor power in 400 V at heavy-duty use
Phd for hp = Typical motor power in 460 V at heavy-duty use
0.75 1.0 4.6 0.75 0.8 3.5 ACS550-01-04A6-2 R1
1.1 1.5 6.6 0.75 1.0 4.6 ACS550-01-06A6-2 R1
1.5 2.0 7.5 1.1 1.5 6.6 ACS550-01-07A5-2 R1
2.2 3.0 11.8 1.5 2.0 7.5 ACS550-01-012A-2 R1
4.0 5.0 16.7 3.0 3.0 11.8 ACS550-01-017A-2 R1
5.5 7.5 24.2 4.0 5.0 16.7 ACS550-01-024A-2 R2
7.5 10.0 30.8 5.5 7.5 24.2 ACS550-01-031A-2 R2
11.0 15.0 46.2 7.5 10.0 30.8 ACS550-01-046A-2 R3
15.0 20.0 59.4 11.0 15.0 46.2 ACS550-01-059A-2 R3
18.5 25.0 74.8 15.0 20.0 59.4 ACS550-01-075A-2 R4
22.0 30.0 88.0 18.5 25.0 74.8 ACS550-01-088A-2 R4
30.0 40.0 114 22.0 30.0 88.0 ACS550-01-114A-2 R4
37.0 50.0 143 30.0 40 114 ACS550-01-143A-2 R6
for A = Continuous rms current. 10% overload is allowed for one minute in ten
minutes.
for A = Continuous rms current. 50% overload is allowed for one minute in ten minutes.
45.0 60.0 178 37.0 50 150 ACS550-01-178A-2 R6
55.0 75.0 221 45.0 60 178 ACS550-01-221A-2 R6
75.0 100 248 55.0 75 192 ACS550-01-248A-2 R6
Wall-mounted drives Free-standing drive
R1 369 330 125 212 6.5 461 213 234 8
R2 469 430 125 222 9 561 213 245 11
R3 583 490 203 231 16 629 257 254 17
R4 689 596 203 262 24 760 257 284 26
R5 736 602 265 286 34 775 369 309 42
R6 8881) 700 302 400 69 9243) 410 423 86
1) ACS550-01-246A-4 and ACS550-01-290A-4: 981 mm
2) UL Type 12 not available for ACS550-01-290A-4
D 3) ACS550-01-290A-4: 1119 mm
W
Free-standing units
H1 = Height with cable connection box
H2 = Height without cable connection box
W = Width
D = Depth
D R8 2024 n/a 3471) 6171) 230
1) The dimensions apply to bookshelf mounting. In flat type mounting the width and depth change places.
n/a = not applicablez
Electromagnetic compatibility
The EMC product standard (EN 61800-3:2004 + Amendment
A1:2012) covers the specific EMC requirements stated for drives (tested with motor and cable) within the EU. EMC standards such as EN 55011, or EN 61000-6-3/4, apply to industrial and household equipment and systems including drive component inside. Drive units complying
with requirements of EN 61800-3 are always complient with comparable categories in EN 55011 and EN 61000-6-3/4, but not necessarily vice versa. EN 55011 and EN 61000-6-3/4 do not specify cable length nor require a motor to be connected as a load. The emission limits are comparable according to
the following table, EMC standards.
EMC standards in general
EMC according to EN61800-3
1st environment restricted distribution for frame sizes R3, R4 with
75 m motor cables and for frame sizes R1, R2, R5, R6 with 100 m motor cables as standard with default switching frequency.
2nd environment unrestricted distribution for frame sizes R1 to R4 with
EN 61800-3/A11 (2000), product standard
EN 61800-3 (2004)
+ A1:2012 product standard
EN 55011, product family standard for industrial, scientific and medical (ISM) equipment
300 m motor cables and for frame sizes R5 to R8 with 100 m motor
cables as standard with default switching frequency. These cable lengths are for EMC purposes only. Operational cable
lengths are available in the output choke selection table on page 11.
1st environment, unrestricted distribution
1st environment,
restricted distribution
Category C1 Group 1
Class B Category C2 Group 1
Class A
For longer motor cable lengths, external EMC filters are available on
2nd environment,
Category C3 Group 2
request.
unrestricted distribution
2nd environment, restricted distribution
Class A Category C4 Not applicable
The assistant control panel, which is delivered as standard, features a multilingual alphanumeric display for easy drive programming. The control panel has various assistants and a built-in help function to guide the user. It includes a real time clock, which can be used during fault logging and in controlling the drive, such as start/stop. The control panel can be used for copying parameters for back up or for
downloading them to another drive. A large graphical display and soft keys make it extremely easy to navigate.
Options
Control interfaces
ACS550 – 01 – 03A3 – 4 + B055
Panel mounting kits
To attach the control panel to the outside of a larger enclosure, two panel mounting kits are available. A simple and cost- efficient installation is possible with the ACS/H-CP-EXT kit, while the OPMP-01 kit provides a more user-friendly solution, including a panel platform that enables the panel to be removed in the same way as a drive-mounted panel. The panel mounting kits include all hardware required, including
3 m extension cables and installation instructions.
How to select options
The options shown in the table are available within the ACS550 range. Most of them have an associated 4-figure option code, which is shown in the table. It is this code that replaces B055
Available options
Protection class
B055 IP54
Control panel
0J400 If no control panel is required J404 Basic control panel ACS-CP-C
– 1) Panel mounting kit ACS/H-CP-EXT
– 1) Panel holder mounting kit OPMP-01
– 1) Panel mounting kit IP66 ACS/H-CP-EXT-IP66
I/O options2)
L511 Relay output extension OREL-01
Control option2)
– 1) Encoder OTAC-01
Fieldbus3)
K451 DeviceNetTM RDNA-01
K452 LonWorks® RLON-01
K454 PROFIBUS DP RPBA-01
K457 CANopen® RCAN-01
K462 ControlNet RCNA-01
K466 Modbus TCP RETA-01
K466 EtherNet/IPTM RETA-01
K467 Modbus TCP RETA-02
K467 PROFINET IO RETA-02
– 1) POWERLINK REPL-02
– 1) EtherCAT® RECA-01
Tools
– 1) FlashDrop MFDT-01
in the type code above. External options require a separate order line and material or type code number.
– 1) DriveWindow Light and
USB serial adapters
Remote monitoring
DriveWindow Light
Basic control panel
The basic control panel features a single line numeric display. The panel can be
used to control the drive, set the parameter values or copy them from one drive to another.
8 ABB general purpose drives ACS550 | Catalog
– 1) Ethernet adapter SREA-01
1) Ordering with a separate material code number.
2) One slot available for relay or encoder.
3) One slot available for fieldbus adapter. Modbus built-in as standard.
FlashDrop tool
ACS550 drives have an interface for a FlashDrop tool. FlashDrop is a powerful palm sized tool for fast and easy parameter selection and setting of an unpowered drive. The user can hide each parameter/group from the drive’s display, which protects the drive and connected machinery. For more information on the FlashDrop tool, please see page 10.
Relay output extension option module
This plug-in option offers three additional relay outputs. They can be used, for example, in pump and fan control or many supervisory functions. All the relays can be programmed
to on/off by using the assistant control panel’s clock. Alternatively, fieldbus can be used to control any external components in the system.
Encoder feedback option module
The general purpose drives can accommodate an encoder module. Using an encoder for speed feedback is a straight forward way to increase motor control in many applications.
Plug-in fieldbus module
The plug-in fieldbus options bring connectivity to major automation systems. A single twisted pair avoids large amounts of conventional cabling,thereby reducing cost and increasing system reliability.
ACS550 supports the following fieldbus options:
− DeviceNetTM
− LonWorks®
− PROFIBUS DP
− CANopen®
− ControlNet
− Modbus TCP
− EtherNet/IPTM
− PROFINET IO
− POWERLINK
− EtherCAT®
For type codes see page 8
Analog I/O
Digital
inputs
Relay outputs
Built-in Modbus
using
EIA-485
Options
External options
FlashDrop tool
FlashDrop is a powerful palm sized tool for fast and easy parameter selecting and setting. It gives the possibility to hide selected parameters to protect the machine. Only the
parameters needed in the application are shown. The tool can copy parameters between two drives or between a PC and a drive. All the above can be done without a power connection to the drive. The interface for FlashDrop is available in all wall- mounted units.
DrivePM
DrivePM (drive parameter manager) is a tool to create, edit and copy parameter sets for the FlashDrop tool. For each parameter/ group the user has a possibility to hide it, which means that the drive user does not see the parameter/group at all.
DrivePM requirements
− Supported operating systems: Windows NT/2000/XP/Vista/7
FlashDrop package includes
− FlashDrop tool
− DrivePM software (CD-rom)
− User’s manual (hardcopy and PDF)
− RS232 cable for connection between PC and the FlashDrop tool
− Battery charger
SREA-01 Ethernet adapter
SREA-01 Ethernet adapter
with remote monitoring access can send process data, data logs and event messages independently, without a PLC or a dedicated on-site computer.
It has an internal web server for configuration and drive access.
DriveWindow Light
DriveWindow Light is an easy-to-use startup and maintenance tool for ACS550 drives. It can be used in an offline mode, which enables parameter setting at the office even before going to the actual site. The parameter browser enables viewing, editing and saving of parameters. The parameter comparison feature makes it possible to compare parameter values between the drive and the file. With the parameter subset you can create your own parameter sets. Controlling
of the drive is naturally one of the features in DriveWindow Light. With this software tool, you can monitor up to four signals simultaneously. This can be done in both graphical and numerical format. Any signal can be set to stop the monitoring from a predefined level.
Startup wizards
Startup wizards make the setting of parameters easy. Simply launch the wizard, select an appropriate assistant eg, for setting analog outputs, and all parameters related to this function are shown together with help pictures.
Highlights
− Editing, saving and downloading parameters
− Graphical and numerical signal monitoring
− Drive control
− Startup wizards
DriveWindow Light requirements
− Supported operating systems: Windows NT/2000/XP/Vista/7
W
Brake units and choppers D
Frame sizes R1 to R2 are delivered with integrated brake choppers as standard. Other units can use the compact-sized brake units which include brake chopper and resistor. For more information please refer to the ACS-BRK brake units installation and startup guide.
Brake units technical data
Frequency converter input voltage
Resistor ohm
Continuous output W
Max. output
20 s W
Brake unit type code
200 to 240 V AC 32 2000 4500 ACS-BRK-C
380 to 480 V AC 12000
200 to 240 V AC 10.5 7000 14000 ACS-BRK-D
380 to 480 V AC 42000 Dimensions
Brake unit
type code
Output chokes
Output chokes are used when motor cables above normal length are required.
Cable can be roughly 1.5 times standard cable length, see
below.
150 500 347 7.5 ACS-BRK-C
270 600 450 20.5 ACS-BRK-D
Type designation Frame size
Nominal current
I2N
A
Output choke type code 1)
Choke thermal current
I
A
Max. cable length without choke 2)
m
Max. cable length with choke 3)
m
UN = 380 to 480 V (380, 400, 415, 440, 460, 480 V)
ACS550-01-03A3-4 R1 3.3 NOCH-0016-6X 19 100 150
ACS550-01-04A1-4 R1 4.1 NOCH-0016-6X 19 100 150
ACS550-01-05A4-4 R1 5.4 NOCH-0016-6X 19 100 150
ACS550-01-06A9-4 R1 6.9 NOCH-0016-6X 19 100 150
ACS550-01-08A8-4 R1 8.8 NOCH-0016-6X 19 100 150 ACS550-01-012A-4 R1 11.9 NOCH-0016-6X 19 100 150
ACS550-01-015A-4 R2 15.4 NOCH-0016-6X 19 200 250
ACS550-01-023A-4 R2 23 NOCH-0030-6X 41 200 250
ACS550-01-031A-4 R3 31 NOCH-0030-6X 41 200 250
ACS550-01-038A-4 R3 38 NOCH-0030-6X 41 200 250 ACS550-01-045A-4 R3 45 NOCH-0070-6X 112 200 300
ACS550-01-059A-4 R4 59 NOCH-0070-6X 112 200 300
ACS550-01-072A-4 R4 72 NOCH-0070-6X 112 200 300
ACS550-01-087A-4 R4 87 NOCH-0070-6X 112 300 300
ACS550-01-125A-4 R5 125 NOCH-0120-6X 157 300 300
ACS550-01-157A-4 R6 157 FOCH-0260-70 289 300 300
ACS550-01-180A-4 R6 180 FOCH-0260-70 289 300 300
ACS550-01-195A-4 R6 205 FOCH-0260-70 289 300 300
ACS550-01-246A-4 R6 246 FOCH-0260-70 289 300 300
ACS550-01-290A-4 R6 290 FOCH-0320-50 445 300 300
ACS550-02-368A-4 R8 368 FOCH-0320-50 445 300 300
ACS550-02-486A-4 R8 486 FOCH-0610-70 720 300 300
ACS550-02-526A-4 R8 526 FOCH-0610-70 720 300 300
ACS550-02-602A-4 R8 602 FOCH-0610-70 720 300 300 ACS550-02-645A-4 R8 645 FOCH-0610-70 720 300 300
1) The last digit of the output choke type defines the degree of protection; X stands for 2 = IP22 or 5 = IP54, 0 = IP00
2) Cable lengths according to 4 kHz switching frequency
3) Maximum switching frequency to be used with du/dt filter is 4 kHz
Note:
An output choke does not improve the EMC performance of the drive. To fulfil local EMC requirements use sufficient RFI filtering.
For more information refer to the ACS550 User’s manual /Technical reference.
Cooling and fuses
Cooling
ACS550 is fitted with cooling air fans. The cooling air must
be free from corrosive materials and not above the maximum ambient temperature of 40 °C (50 °C with derating). For more specific environmental limits see page 5.
Fuse connections
Standard fuses can be used with ABB general purpose drives. For input fuse connections see tables below.
Cooling air flow 380 to 480 V units
Type designation Frame Heat dissipation Air flow
size W BTU/Hr m3/h ft3/min
ACS550-01-03A3-4 R1 40 137 44 26
ACS550-01-04A1-4 R1 52 178 44 26
ACS550-01-05A4-4 R1 73 249 44 26
ACS550-01-06A9-4 R1 97 331 44 26
ACS550-01-08A8-4 R1 127 434 44 26 ACS550-01-012A-4 R1 172 587 44 26
ACS550-01-015A-4 R2 232 792 88 52
ACS550-01-023A-4 R2 337 1151 88 52
ACS550-01-031A-4 R3 457 1561 134 79
ACS550-01-038A-4 R3 562 1919 134 79 ACS550-01-045A-4 R3 667 2278 134 79
ACS550-01-059A-4 R4 907 3098 280 165
ACS550-01-072A-4 R4 1120 3825 280 165
ACS550-01-087A-4 R4 1440 4918 280 165
ACS550-01-125A-4 R5 1940 6625 350 205
ACS550-01-157A-4 R6 2310 7889 405 238
ACS550-01-180A-4 R6 2810 9597 405 238
ACS550-01-195A-4 R6 3050 10416 405 238
ACS550-01-246A-4 R6 3260 11134 405 238
ACS550-01-290A-4 R6 3850 13125 405 238
ACS550-02-368A-4 R8 6850 23394 1220 718
ACS550-02-486A-4 R8 7850 26809 1220 718
ACS550-02-526A-4 R8 7600 25955 1220 718
ACS550-02-602A-4 R8 8100 27663 1220 718 ACS550-02-645A-4 R8 9100 31078 1220 718
Recommended input protection fuses for 380 to 480 V units
Type designation Frame IEC fuses UL fuses
size A Fuse type *) A Fuse type
ACS550-01-03A3-4 R1 10 gG 10 UL Class T
ACS550-01-04A1-4 R1 10 gG 10 UL Class T
ACS550-01-05A4-4 R1 10 gG 10 UL Class T
ACS550-01-06A9-4 R1 10 gG 10 UL Class T
ACS550-01-08A8-4 R1 10 gG 15 UL Class T ACS550-01-012A-4 R1 16 gG 15 UL Class T ACS550-01-015A-4 R2 16 gG 20 UL Class T ACS550-01-023A-4 R2 25 gG 30 UL Class T
ACS550-01-031A-4 R3 35 gG 40 UL Class T
ACS550-01-038A-4 R3 50 gG 50 UL Class T ACS550-01-045A-4 R3 50 gG 60 UL Class T ACS550-01-059A-4 R4 63 gG 80 UL Class T ACS550-01-072A-4 R4 80 gG 90 UL Class T ACS550-01-087A-4 R4 125 gG 125 UL Class T ACS550-01-125A-4 R5 160 gG 175 UL Class T ACS550-01-157A-4 R6 200 gG 200 UL Class T ACS550-01-180A-4 R6 250 gG 250 UL Class T ACS550-01-195A-4 R6 250 gG 250 UL Class T ACS550-01-246A-4 R6 250 gG 250 UL Class T ACS550-01-290A-4 R6 315 gG 315 UL Class T
ACS550-02-368A-4 R8 400 gG 400 UL Class T
ACS550-02-486A-4 R8 500 gG 500 UL Class T
ACS550-02-526A-4 R8 630 gG 630 UL Class T
ACS550-02-602A-4 R8 630 gG 630 UL Class T ACS550-02-645A-4 R8 800 gG 800 UL Class T
Cooling air flow 208 to 240 V units
Type designation Frame Heat dissipation Air flow
size W BTU/Hr m3/h ft3/min
ACS550-01-04A6-2 R1 55 189 44 26
ACS550-01-06A6-2 R1 73 249 44 26
ACS550-01-07A5-2 R1 81 276 44 26
ACS550-01-012A-2 R1 118 404 44 26 ACS550-01-017A-2 R1 161 551 44 26
ACS550-01-024A-2 R2 227 776 88 52
ACS550-01-031A-2 R2 285 973 88 52
ACS550-01-046A-2 R3 420 1434 134 79 ACS550-01-059A-2 R3 536 1829 134 79
ACS550-01-075A-2 R4 671 2290 280 165
ACS550-01-088A-2 R4 786 2685 280 165
ACS550-01-114A-2 R4 1014 3463 280 165
ACS550-01-143A-2 R6 1268 4331 405 238
ACS550-01-178A-2 R6 1575 5379 405 238
ACS550-01-221A-2 R6 1952 6666 405 238 ACS550-01-248A-2 R6 2189 7474 405 238
Recommended input protection fuses for 208 to 240 V units
Type designation Frame IEC fuses UL fuses
size A Fuse type *) A Fuse type
ACS550-01-04A6-2 R1 10 gG 10 UL Class T
ACS550-01-06A6-2 R1 10 gG 10 UL Class T
ACS550-01-07A5-2 R1 10 gG 10 UL Class T
ACS550-01-012A-2 R1 16 gG 15 UL Class T ACS550-01-017A-2 R1 25 gG 25 UL Class T ACS550-01-024A-2 R2 25 gG 30 UL Class T ACS550-01-031A-2 R2 40 gG 40 UL Class T
ACS550-01-046A-2 R3 63 gG 60 UL Class T ACS550-01-059A-2 R3 63 gG 80 UL Class T ACS550-01-075A-2 R4 80 gG 100 UL Class T ACS550-01-088A-2 R4 100 gG 110 UL Class T ACS550-01-114A-2 R4 125 gG 150 UL Class T
ACS550-01-143A-2 R6 200 gG 200 UL Class T
ACS550-01-178A-2 R6 250 gG 250 UL Class T
ACS550-01-221A-2 R6 315 gG 300 UL Class T ACS550-01-248A-2 R6 315 gG 350 UL Class T
Free space requirements
Enclosure type Space above mm
Space below mm
Space on left/right mm
Wall mounted 200 200 0
Free standing 200 0 0
*) According to IEC-60269 standard
Control connections
These connections are shown as examples only. Please refer to the ACS550 User’s manual, chapter Installations, for more detailed information.
Signal termination is selected by DIP switch
Drives service
Your choice, your future
The future of your drives depends on the service you choose.
Whatever you choose, it should be a well-informed decision. No guesswork. We have the expertise and experience to help you find and implement the right service for your drive
equipment. You can start by asking yourself these two critical questions:
− Why should my drive be serviced?
− What would my optimal service options be?
From here, you have our guidance and full support along the course you take, throughout the entire lifetime of your drives.
Your choice, your business efficiency
ABB Drive Care agreement lets you focus on your core business. A selection of predefined service options matching your needs provides optimal, more reliable performance, extended drive lifetime and improved cost control. So you can reduce the risk of unplanned downtime and find it easier to budget for maintenance.
We can help you more by knowing where you are! Register your drive at www.abb.com/drivereg for extended warranty options and other benefits.
Service to match your needs
Your service needs depend on your operation, life cycle of your equipment and business priorities. We have identified our customers’ four most common needs and defined service options to satisfy them. What is your choice to keep your drives at peak performance?
Is uptime your priority?
Keep your drives running with precisely planned and executed maintenance.
Example services include: Life Cycle Assessment Installation and
Commissioning
Spare Parts
Preventive Maintenance
Reconditioning
ABB Drive Care agreement
Drive Exchange
Is rapid response a key consideration?
If your drives require immediate action, our global network is at your service.
Example services include:
Technical Support On-site Repair Remote Support
Response time agreements
Training
Need to extend your assets’ lifetime?
Maximize your drive’s lifetime with our services.
Example services include: Life Cycle Assessment Upgrades, Retrofits and
Modernization
Replacement, Disposal and
Recycling
Is performance most critical to your operation?
Get optimal performance out of your machinery and systems.
Example services include: Advanced services Engineering and Consulting Inspection and Diagnostics Upgrades, Retrofits and
Modernization
Workshop Repair
Tailored services
24
Rapid response
Life cycle management
Operational efficiency
Performance improvement
Drives service
A lifetime of peak performance
You’re in control of every life cycle phase of your drives. At the heart of drive services is a four-phase product life cycle management model. This model defines the services recommended and available throughout drives lifespan.
Now it’s easy for you to see the exact service and maintenance available for your drives.
ABB drives life cycle phases explained:
Active Classic Limited Obsolete
Full range of life cycle services and support Limited range of life cycle services and support
Replacement and end-of-life services
Product is in active sales and manufacturing phase.
Full range of life cycle services is available.
Serial production has ceased. Product may be available for plant extensions, as a spare part or for installed base renewal.
Full range of life cycle services is available.
Product enhancements may be available through upgrade and retrofit solutions.
Product is no longer available.
Limited range of life cycle services is available.
Spare parts availability is limited to available stock.
Product is no longer available.
Replacement and end-of-life services are available.
Keeping you informed
We notify you every step of the way using life cycle status statements and announcements.
Your benefit is clear information about your drives’ status
and precise services available. It helps you plan the preferred service actions ahead of time and make sure that continuous support is always available.
Life Cycle Status Announcement
Provides early information about the upcoming life cycle phase change and how it affects the availability of services.
Life Cycle Status Statement
Provides information about the drive’s current life cycle status, availability of product and services, life cycle plan and recommended actions.
Contact us
For more information please contact your Swastik Services
representative or visit:
www.swastikdrive.com